Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38534234

RESUMO

Ultrasound A-scan is an important tool for quantitative assessment of ocular lesions. However, its usability is limited by the difficulty of accurately localizing the ultrasound probe to a lesion of interest. In this study, a transparent LiNbO3 single crystal ultrasound transducer was fabricated, and integrated with a widefield fundus camera to guide the ultrasound local position. The electrical impedance, phase spectrum, pulse-echo performance, and optical transmission spectrum of the ultrasound transducer were validated. The novel fundus camera-guided ultrasound probe was tested for in vivo measurement of rat eyes. Anterior and posterior segments of the rat eye could be unambiguously differentiated with the fundus photography-guided ultrasound measurement. A model eye was also used to verify the imaging performance of the prototype device in the human eye. The prototype shows the potential of being used in the clinic to accurately measure the thickness and echogenicity of ocular lesions in vivo.


Assuntos
Angiofluoresceinografia , Ratos , Animais , Humanos , Angiofluoresceinografia/métodos , Ultrassonografia
2.
IEEE Trans Biomed Eng ; 70(4): 1310-1317, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36260593

RESUMO

OBJECTIVE: Current elastography techniques in the field of ophthalmology usually target one specific tissue, such as the cornea or the sclera. However, the eye is an inter-related organ, and some ocular diseases can alter the biomechanical properties of multiple anatomical structures. Hence, there is a need to develop an imaging tool that can non-invasively, quantitatively, and accurately characterize dynamic changes among these biomechanical properties. METHODS: A high resolution ultrasound elastography system was developed to achieve this goal. The efficacy and accuracy of the system was first validated on tissue-mimicking phantoms while mechanical testing measurements served as the gold standard. Next, an in vivo elevated intraocular pressure (IOP) model was established in rabbits to further test our system. In particular, elastography measurements were obtained at 5 IOP levels, ranging from 10 mmHg to 30 mmHg in 5 mmHg increments. Spatial-temporal maps of the multiple ocular tissues (cornea, lens, iris, optic nerve head, and peripapillary sclera) were obtained. RESULTS: The spatial-temporal maps were acquired simultaneously for the ocular tissues at the 5 different IOP levels. The statistical analysis of the elastic wave speed was presented for ocular tissues. Finally, the mapping for the elastic wave speed of each ocular component was acquired at each IOP level. CONCLUSION: Our elastography system can concurrently assess the biomechanical properties of multiple ocular structures and detect changes in biomechanical properties associated with changes in IOP. SIGNIFICANCE: This system provides a novel tool to measure and quantify the biomechanical properties of the whole eye.


Assuntos
Técnicas de Imagem por Elasticidade , Ultrassom , Animais , Coelhos , Fenômenos Biomecânicos , Som , Córnea/diagnóstico por imagem
3.
JAMA Ophthalmol ; 138(1): 40-47, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31725830

RESUMO

Importance: Anti-vascular endothelial growth factor (anti-VEGF) is a breakthrough treatment for wet age-related macular degeneration (wAMD), the most common cause of blindness in western countries. Anti-VEGF treatment prevents vision loss and has been shown to produce vision gains lasting as long as 5 years. Although this treatment is costly, the benefits associated with vision gains are large. Objective: To estimate the economic value of benefits, costs for patients with wAMD, and societal value in the United States generated from vision improvement associated with anti-VEGF treatment. Design, Setting, and Participants: This economic evaluation study used data from the published literature to simulate vision outcomes for a cohort of 168 820 patients with wAMD aged 65 years or older and to translate them into economic variables. Data were collected and analyzed from March 2018 to November 2018. Main Outcomes and Measures: Main outcomes included patient benefits, costs, and societal value. Each outcome was estimated for a newly diagnosed cohort and the full population across 5 years, with a focus on year 3 as the primary outcome because data beyond that point may be less representative of the general population. Drug costs were the weighted mean across anti-VEGF therapies. Two current treatment scenarios were considered: less frequent injections (mean [SD], 8.2 [1.6] injections annually) and more frequent injections (mean [range], 10.5 [6.8-13.1] injections annually). The 2 treatment innovation scenarios, improved adherence and best case, had the same vision outcomes as the current treatment scenarios had but included more patients treated from higher initiation and lower discontinuation. Results: The study population included 168 820 patients aged 65 years at the time of diagnosis with wAMD. The underlying clinical trials that were used to parameterize the model did not stratify visual acuity outcomes or treatment frequency by sex; therefore, the model parameters could not be stratified by sex. The current treatment scenario of less frequent injections generated $1.1 billion for the full population in year 1 and $5.1 billion in year 3, whereas the scenario of more frequent injections generated $1.6 billion (year 1) and $8.2 billion (year 3). Three-year benefits ranged from $7.3 billion to $11.4 billion in the improved adherence scenario and from $9.7 billion to $15.0 billion if 100% of the patients initiated anti-VEGF treatment and the discontinuation rates were 6% per year or equivalent to clinical trial discontinuation (best-case scenario). Societal value (patient benefits net of treatment cost) ranged from $0.9 billion to $3.0 billion across 3 years in the current treatment scenarios and from $0.9 billion to $4.3 billion in the treatment innovation scenarios. Conclusions and Relevance: This study's findings suggest that improved vision associated with anti-VEGF treatment may provide economic value to patients and society if the outcomes match published outcomes data used in these analyses; however, future innovations that increase treatment utilization may result in added economic benefit.


Assuntos
Inibidores da Angiogênese/economia , Neovascularização de Coroide/economia , Análise Custo-Benefício/economia , Degeneração Macular Exsudativa/economia , Idoso , Idoso de 80 Anos ou mais , Neovascularização de Coroide/tratamento farmacológico , Neovascularização de Coroide/fisiopatologia , Custos de Medicamentos , Feminino , Custos de Cuidados de Saúde , Humanos , Injeções Intravítreas , Masculino , Anos de Vida Ajustados por Qualidade de Vida , Tomografia de Coerência Óptica , Estados Unidos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual/fisiologia , Degeneração Macular Exsudativa/tratamento farmacológico , Degeneração Macular Exsudativa/fisiopatologia
4.
Transl Vis Sci Technol ; 8(3): 31, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31171998

RESUMO

PURPOSE: To characterize histologic changes in the optic nerve and the retina of an end-stage retinitis pigmentosa (RP) patient after long-term implantation with the Argus II retinal prosthesis system. METHODS: Serial cross sections from the patient's both eyes were collected postmortem 6 years after implantation. Optic nerve from both eyes were morphometrically analyzed and compared. Retina underneath and outside the array was analyzed and compared with corresponding regions in the fellow eye. RESULTS: Although the optic nerve of the implant eye demonstrated significantly more overall atrophy than the fellow eye (P < 0.01), the temporal quadrant that retinotopically corresponded to the location of the array did not show additional damage. The total neuron count of the macular area was not significantly different between the two eyes, but the tack locations and their adjacent areas showed significantly fewer neurons than other perimacular areas. There was an increased expression of glial fibrillary acidic protein (GFAP) throughout the retina in the implant eye versus the fellow eye, but there was no significant difference in the cellular retinaldehyde-binding protein (CRALBP) expression. Except for the revision tack site, no significant increase of inflammatory reaction was detected in the implant eye. CONCLUSION: Long-term implantation and electrical stimulation with an Argus II retinal prosthesis system did not result in significant tissue damage that could be detected by a morphometric analysis. TRANSLATIONAL RELEVANCE: This study supports the long-term safety of the Argus II device and encourages further development of bioelectronics devices at the retina-machine interface.

5.
JAMA Ophthalmol ; 137(8): 939-944, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31169870

RESUMO

IMPORTANCE: The US Food and Drug Administration's medical device regulatory pathway was initially conceived with hardware devices in mind. The emerging market for ophthalmic digital devices necessitates an evolution of this paradigm. OBJECTIVES: To facilitate innovation in ophthalmic digital health with attention to safety and effectiveness. EVIDENCE REVIEW: This article presents a summary of the presentations, discussions, and literature review that occurred during a joint Ophthalmic Digital Health workshop of the American Academy of Ophthalmology, the American Academy of Pediatrics, the American Association for Pediatric Ophthalmology and Strabismus, the American Society of Cataract and Refractive Surgery, the American Society of Retina Specialists, the Byers Eye Institute at Stanford and the US Food and Drug Administration. FINDINGS: Criterion standards and expert graders are critically important in the evaluation of automated systems and telemedicine platforms. Training at all levels is important for the safe and effective operation of digital health devices. The risks associated with automation are substantially increased in rapidly progressive diseases. Cybersecurity and patient privacy warrant meticulous attention. CONCLUSIONS AND RELEVANCE: With appropriate attention to safety and effectiveness, digital health technology could improve screening and treatment of ophthalmic diseases and improve access to care.

6.
Stem Cells Int ; 2017: 9428176, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28928775

RESUMO

Dysfunction and death of retinal pigment epithelium (RPE) and or photoreceptors can lead to irreversible vision loss. The eye represents an ideal microenvironment for stem cell-based therapy. It is considered an "immune privileged" site, and the number of cells needed for therapy is relatively low for the area of focused vision (macula). Further, surgical placement of stem cell-derived grafts (RPE, retinal progenitors, and photoreceptor precursors) into the vitreous cavity or subretinal space has been well established. For preclinical tests, assessments of stem cell-derived graft survival and functionality are conducted in animal models by various noninvasive approaches and imaging modalities. In vivo experiments conducted in animal models based on replacing photoreceptors and/or RPE cells have shown survival and functionality of the transplanted cells, rescue of the host retina, and improvement of visual function. Based on the positive results obtained from these animal experiments, human clinical trials are being initiated. Despite such progress in stem cell research, ethical, regulatory, safety, and technical difficulties still remain a challenge for the transformation of this technique into a standard clinical approach. In this review, the current status of preclinical safety and efficacy studies for retinal cell replacement therapies conducted in animal models will be discussed.

7.
J Biomed Opt ; 20(8): 88001, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26252627

RESUMO

Transcranial near-infrared (NIR) treatment of neurological diseases has gained recent momentum. However, the low NIR dose available to the brain, which shows severe scattering and absorption of the photons by human tissues, largely limits its effectiveness in clinical use. Hereby, we propose to take advantage of the strong scattering effect of the cranial tissues by applying an evenly distributed multiunit emitter array on the scalp to enhance the cerebral photon density while maintaining each single emitter operating under the safe thermal limit. By employing the Monte Carlo method, we simulated the transcranial propagation of the array emitted light and demonstrated markedly enhanced intracranial photon flux as well as improved uniformity of the photon distribution. These enhancements are correlated with the source location, density, and wavelength of light. To the best of our knowledge, we present the first systematic analysis of the intracranial light field established by the scalp-applied multisource array and reveal a strategy for the optimization of the therapeutic effects of the NIR radiation.


Assuntos
Encéfalo/fisiologia , Raios Infravermelhos , Modelos Estatísticos , Estimulação Luminosa/instrumentação , Fototerapia/instrumentação , Semicondutores , Absorção de Radiação , Encéfalo/efeitos da radiação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Modelos Neurológicos , Método de Monte Carlo , Doses de Radiação , Espalhamento de Radiação
8.
Retina ; 34(9): 1854-60, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24732694

RESUMO

PURPOSE: This pilot study was aimed to demonstrate the clinical feasibility of using hyperspectral computed tomographic spectroscopy to measure blood oxygen content in human retinal vessels. METHODS: All procedures were performed under a University of Southern California Institutional Review Board-approved protocol and after obtaining informed consent. Fifty-seven subjects with and without diabetic retinopathy were dilated for standard fundus photography. Fundus photographs and retinal vascular oxygen measurements (oximetry) were made using a custom-made hyperspectral computed tomographic imaging spectrometer coupled to a standard fundus camera. Oximetry measurements were made along arteries (Aox) and veins (Vox) within vessel segments that were 1 to 2 disk diameters from the optic disk. RESULTS: For all control subjects (n = 45), mean Aox and Vox were 93 ± 7% and 65 ± 5% (P = 0.001), respectively. For all diabetic subjects (n = 12), mean Aox and Vox were 90 ± 7% and 68 ± 5% (P = 0.001), respectively. In subjects with proliferative diabetic retinopathy, Aox was significantly lower, and Vox was significantly higher than other groups (85 ± 4% and 71 ± 4%, respectively; P = 0.04, analysis of variance). There was a highly significant difference in the arteriovenous difference between subjects with proliferative diabetic retinopathy and those in the control group (14 vs. 26%, P = 0.003). CONCLUSION: Hyperspectral computed tomographic spectroscopy is a clinically feasible method for measurement and analysis of vascular oxygen content in retinal health and disease. This study uses the techniques relevant to oximetry; however, the breadth of spectral data available through this method may be applicable to study other anatomical and functional features of the retina in health and disease.


Assuntos
Retinopatia Diabética/fisiopatologia , Técnicas de Diagnóstico Oftalmológico , Oxigênio/sangue , Vasos Retinianos/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Glicemia/metabolismo , Feminino , Angiofluoresceinografia , Hemoglobinas Glicadas/metabolismo , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria/métodos , Projetos Piloto , Análise Espectral , Tomografia Computadorizada por Raios X
9.
Magn Reson Imaging ; 30(3): 382-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22260934

RESUMO

OBJECTIVE: The objective was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, heating, artifacts and functional alterations) at 1.5 T and 3 T for the Argus II Retinal Prosthesis (Second Sight Medical Products, Sylmar, CA, USA). MATERIALS AND METHODS: Standardized protocols were used to assess magnetic field interactions (translational attraction and torque; 3 T, worst case), MRI-related heating (1.5 and 3 T), artifacts (3 T; worst case) and functional changes (1.5 and 3 T) associated with MRI. RESULTS: The magnetic field interactions were acceptable. MRI-related heating, which was studied at a relatively high, MR system-reported whole body averaged specific absorption rates, will not pose a hazard to the patient under the conditions used for testing. While artifacts were "moderate" in relation to the dimensions of the Argus II Retinal Prosthesis, optimization of MRI parameters can reduce the size of the artifacts. Exposures to MRI conditions at 1.5 and 3 T did not damage or alter the functional aspects of the Argus II Retinal Prosthesis. CONCLUSIONS: In consideration of the test results, a patient with the Argus II Retinal Prosthesis may undergo MRI at 1.5 T or 3 T when specific guidelines and MRI conditions are followed, including those advised by the manufacturer.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próteses Visuais , Artefatos , Segurança de Equipamentos , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Medição de Risco , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA